Types of Natural Ventilation Effects



Wind can blow air through openings in the wall on the windward side of the building, and suck air out of openings on the leeward side and the roof. Temperature differences between warm air inside and cool air outside can cause the air in the room to rise and exit at the ceiling or ridge, and enter via lower openings in the wall. Similarly, buoyancy caused by differences in humidity can allow a pressurized column of dense, evaporatively cooled air to supply a space, and lighter, warmer, humid air to exhaust near the top.

Power Ventilation. Power ventilation can be accomplished in two ways. In homes not mechanically cooled (air conditioned) the temperature can be controlled to some extent by the use of attic fans. These fans are usually ceiling mounted in a central hallway so that outside air is pulled through open windows and exhausted through the attic. Sufficient outlets must be installed in the attic to exhaust the air without creating high pressures against which the fan must operate. The net area of attic outlets should be 1/800th of the rated fan volume in cfm and 1/8 inch static pressure. The outlets should be distributed uniformly.

Air conditioned homes can use power attic ventilators by installing an exhaust fan through the roof or in the gable. Inlets for the ventilating air should be at the soffit, or the opposite gable, when no roof overhang exists.

Power ventilators have the advantage of providing good ventilation even when there is no wind. They also provide limited attic temperature control when installed in conjunction with a thermostat. For well-insulated ceilings (i.e. insulation levels of R-19 or above) it is doubtful that power ventilation can be justified economically.

However, there are some attics which cannot be ventilated by gravity or wind-assisted methods, and in these the power vent is necessary for moisture and temperature control.

For areas of Texas where blowing dust and sand are a problem, consideration should be given to the use of a power ventilator with automatic or motorized inlet louvers which close when the fan is not in operation. Ventilation can be shut off during a dust storm to prevent the buildup of dust and sand in the attic.

The coefficient of effectiveness depends on the angle of the wind and the relative size of entry and exit openings. It ranges from about 0.4 for wind hitting an opening at a 45° angle of incidence to 0.8 for wind hitting directly at a 90° angle.

Sometimes wind flow prevails parallel to a building wall rather than perpendicular to it. In this case it is still possible to induce wind ventilation by architectural features or by the way a casement window opens. For example, if the wind blows from east to west along a north-facing wall, the first window (which opens out) would have hinges on the left-hand side to act as a scoop and direct wind into the room. The second window would hinge on the right-hand side so the opening is down-wind from the open glass pane and the negative pressure draws air out of the room.

It is important to avoid obstructions between the windward inlets and leeward exhaust openings. Avoid partitions in a room oriented perpendicular to the airflow. On the other hand, accepted design avoids inlet and outlet windows directly across from each other (you shouldn't be able to see through the building, in one window and out the other), in order to promote more mixing and improve the effectiveness of the ventilation.